Contrec 515 – DP01

  • Net Oil Computer

Density Converter (Liquid)

The density converter application accepts inputs from Sarasota density meters, temperature and pressure transmitters, and an unassigned input enabling a variable to be connected as an input to the Customer Defined Function (look-up table).

The converter calculates line (measured) density from the density meter period output and uses it together with temperature and pressure readings to derive density at reference conditions and calculate specific gravity and other density related variables.
This instrument is compatible with a wide range of density meter pulse outputs, including millivolt signals, reed switches, Namur proximity switches and pulse trains via its smart front-panel program selection.

Calculations

The line density calculations are based on accurately measured average period of pulses coming from density meters such as Sarasota Industrial ensity Meter FD910, etc.
The density conversion to reference conditions is based on the ASTM D1250-04 standard for the following products:

• Crude Oils
• Lube Oils
• Refined Products

The density conversion for general liquids is done by using compressibility and thermal expansion coefficients.